A manufacturer specializing in the production and research and development of testing machines, integrating pre-sales consultation, research and development, production, manufacturing, and service
Current location:
Home >
News>
Company News>Universal Tensile Strength Testing Machine: Selecting an Extensometer
A universal tensile strength testing machine may need an extensometer when the required result depends on specimen strain. Selecting that device involves gauge length, measuring range, resolution, material behaviour, and the test sequence. It also requires a clear distinction between specimen extension and the machine's crosshead movement. This guide explains how to connect a deformation measurement choice to the property the laboratory needs to report.
WDW-50 — Microcomputer controlled electronic universal testing machine. Product illustration. Confirm the exact configuration for your specimens.
Choose the deformation channel for the property
Begin with the calculation. Maximum-force strength and a property calculated from a small-strain region do not require the same measurement information. Modulus and proof-strength work demand a suitable strain record and approved analysis settings. A specimen with large extension adds range and handling considerations. State each requested property explicitly in the RFQ so that the deformation arrangement can be evaluated against it.
Define the original gauge length and how the extensometer is mounted, zeroed, and removed if necessary. Ask what happens when the specimen yields or breaks. If the procedure changes measurement channels during the test, document that transition and its effect on the reported properties. Contact devices and optical approaches have different specimen-access and surface requirements, so the intended material should be part of the demonstration.
Review verification and everyday handling with the same care as the load cell. The device's specified range should cover the part of the curve needed for the property, and its verification should support the intended use. Training should show how to avoid introducing damage or movement during mounting. A suitable device is one that the laboratory can use consistently through the required sequence, rather than one selected only from its maximum extension.
An illustrative application review
In an illustrative comparison, one laboratory needs proof strength on metal coupons and another needs elongation over a much larger range on polymer specimens. A single device may not be appropriate for both. The buyers describe gauge lengths, required properties, and test sequences, then review the proposed sensors and verification. The demonstration includes mounting and removal because these actions can affect the quality of the recorded strain even when the device's catalogue specifications appear adequate.
Separate specimen strain from crosshead travel
Crosshead travel includes more than the extension of the measured specimen length. Grip seating, frame deformation, fixture compliance, and occasional slippage also contribute to the movement recorded by the machine. Consequently, a smooth travel curve cannot by itself establish an accurate elastic modulus or proof strength. Identify which reported properties require an extensometer and specify its gauge length, measuring range, resolution, and applicable verification.
For specimens that extend substantially, consider how the extensometer behaves after yielding and near fracture. Some devices must be removed before break, while others can follow larger deformation. Contact and non-contact solutions have different mounting and surface requirements. Demonstrate the actual measurement sequence with a representative specimen. Record any change from extensometer feedback to another measurement channel in the method and report so that later readers can interpret the resulting curve correctly.
Review modulus and proof-strength calculations separately
Calculations based on a small-strain region require close attention to strain measurement, specimen seating, force measurement, and the selected fitting interval. A result can look plausible while being affected by an inappropriate zero, grip seating, or use of crosshead travel in place of specimen extension. State the calculation required by the chosen method and identify the channels that support it.
During method validation, review the beginning of the curve at a suitable scale and compare the calculated result with the recorded inputs. Define any permitted initial-region treatment and avoid choosing a fitting interval solely to obtain an expected value. For proof strength, document the offset and related settings. Preserve the calculation configuration with the test. This allows another qualified reviewer to distinguish a genuine material response from a change introduced by the analysis settings.
Distinguish metal strength from the measurement choices
A metal tensile test can produce several different properties, including tensile strength, proof strength, and elongation. Each property depends on the chosen method and the relevant measurement channels. Maximum force divided by original area provides engineering tensile strength, while a proof-strength calculation requires an appropriate strain record and an explicitly defined offset. These quantities should have separate names and units in the report.
Record specimen form, preparation, orientation, original dimensions, gauge length, and the method version. A machined round specimen and an as-received bar may follow different requirements even when both originate from the same grade of steel. Review fracture position and any evidence of slippage before accepting the result. A reasonable-looking strength value does not prove that every measurement step complied with the agreed procedure or that elongation was determined in the required way.
Match polymer testing to the specimen form
A moulded dumbbell, a thin film strip, and a coupon cut from a pipe can require different preparation methods, gripping arrangements, and test procedures. Polymer results can depend strongly on temperature, conditioning, specimen geometry, and rate. The laboratory should identify the applicable material and product method before selecting the machine program or comparing two supplier datasheets.
For a plastics project, ask which properties must be reported and how deformation will be measured at both small and large extension. Grip pressure that works for a thick rigid coupon may damage a thin specimen, while a device suitable for high extension may not provide the resolution needed for modulus. Demonstrate the entire sequence with the intended material. Document the sampling direction and processing history where relevant, because changes in the material and changes in the measurement setup can otherwise look similar in the final results.
Specify the controlled quantity and the rate sequence
A test speed written as a single number may hide several different requirements. A method might control crosshead motion, force, stress, strain, or another signal during different stages. These quantities are related, but their numerical rates cannot be substituted without accounting for specimen geometry and the behaviour of the test system. The selected control signal must be measured and available over the relevant stage.
Ask for a demonstration of transitions between stages, including the approach to the specimen, the initial loading region, yielding, and the stopping condition. Inspect the recorded control history rather than relying only on the final strength value. A well-defined method also identifies the permitted operator actions. Saving the full rate sequence with the test record makes it easier to distinguish an equipment problem from a method setting that changed between otherwise similar batches.
Keep the curve and its calculation history
A final maximum-load number is useful for screening, but it does not preserve enough information to investigate every later question. Retain the force, displacement, and strain channels relevant to the method, together with sampling settings, specimen dimensions, gauge length, and the calculation configuration. Link the data to the specimen identifier and the exact test method version.
Ask how the software handles zeroing, filtering, interpolation, excluded regions, and recalculation after a test. The objective is an understandable record rather than the largest possible file. Separate original measurements from edited presentations and identify any post-processing used to create a customer report. Export a sample dataset during acceptance and reopen it on the intended office system. This simple exercise often reveals missing units, ambiguous column names, or software dependencies before production testing begins.
Record conditioning and laboratory conditions
Temperature and prior conditioning can affect material response and the measuring equipment. This is especially significant for polymers, elastomers, and moisture-sensitive materials, but environmental records also help investigate inconsistencies in metal testing. Specify the required conditioning procedure and test environment from the applicable method and product specification. Avoid assuming that time spent next to the machine is an adequate conditioning process.
If an environmental chamber is required, confirm the usable space with the actual grips, extensometer, and specimen installed. Check how the specimen temperature is established and recorded, how cables and sensors enter the chamber, and how the operator changes specimens. A chamber's stated temperature capability is only one part of a usable test arrangement. The laboratory should be able to explain which environmental conditions applied to each specimen and whether any departure affected the interpretation of its result.
Control specimen dimensions before pressing start
Engineering stress is calculated using the original specimen cross-sectional area, so a dimension error becomes a stress error. Measure the relevant width, thickness, or diameter at the locations and with the instruments specified by the chosen method. Rounded nominal dimensions copied from a material catalogue may not describe the actual specimen used in the test.
Preparation also affects the result through edge quality, machining marks, curvature, and changes introduced by cutting or heating. Identify the parent material, sampling location, and orientation before reducing it to a test piece. For comparative work, keep preparation consistent and record exceptions. If a specimen falls outside the required geometry, make the disposition visible in the report. Changing dimensions in the software after seeing an unexpected result cannot repair an unsuitable specimen or an undocumented preparation process.
Frequently asked questions
Can crosshead travel always replace an extensometer?
Crosshead travel includes movement in the machine and fixtures as well as the specimen. Whether it is acceptable depends on the property and method. Define the required deformation measurement explicitly, particularly for small-strain calculations.
What should I send with a configuration inquiry?
Send specimen drawings or photographs, material and dimension ranges, expected forces, required properties, test methods, workload, and installation conditions. Ask the supplier to identify the proposed sensors, grips, software functions, verification, and acceptance procedure. A representative sample demonstration can help resolve details that a model name alone cannot establish.
Discuss the application with Jinan Jianke
Jinan Jianke supplies material testing equipment for laboratory and production applications. Use the WDW-50 product page as a starting point for an application discussion. Send your specimen information and required method through our contact page, and request a configuration-specific proposal, documentation, and representative test evidence.
Standards references
Identify the method applicable to your material and contract, and consult its full requirements. Relevant official catalogue entries include ISO 6892-1, ASTM E8/E8M, ISO 9513. Listing a standard does not establish conformity of a particular machine configuration or completed test.
Talk to an application specialist
Request a Quote